Overview
The Allen-Bradley 440S-SF8D is a GuardLink-enabled connection tap that integrates 8-pin M12 OSSD contacts for machine safety and guarding applications. GuardLink is a safety-based communications protocol that links safety to The Connected Enterprise, with Guardmaster smart safety devices delivering information, advanced functionality and flexibility while enhancing safety and increasing efficiency machine- and plant-wide. This smart tap bridges safety devices to the Guardmaster GuardLink system with output switching signal contacts suitable for Power to Release (PTR) guard locking systems.
Key Features
- Reduces installation cost and promotes system modularity
- M12 8-pin connector with OSSD output switching signal contacts
- Requires 24V DC Class 2 power source
- ABS plastic construction with -25 to 70°C operating temperature rating
- Certifications: CCC, CE, CUL, KC, RCM, UL
- Compatible with Guardmaster Dual GuardLink safety relay systems for individual guard door and e-stop visibility
Technical Specifications
| Model | 440S-SF8D |
| Connector Type | M12 8-Pin Female |
| Contact Type | OSSD (Output Switching Signal Device) – Solid State |
| Power Supply | 24V DC Class 2 |
| Operating Temperature | -25°C to +70°C |
| Storage Temperature | -40°C to +85°C |
| Environmental Humidity | 35–85% Relative Humidity (non-condensing) |
| Material | ABS Plastic |
| Weight | 0.09 lb (41 g) |
| Dimensions | 57 × 79.64 × 17 mm (2.24 × 3.13 × 0.67 in) |
| Certifications | CCC, CE, CUL, KC, RCM, UL |
| Fastener Size | M5 (mounting torque: 2.20 N·m / 19.95 in·lb) |
| Condition | New – No Box |
| UPC | 889508697581 |
Typical Applications
- Machine guarding and personnel safety systems using GuardLink safety networks
- Guard door interlocking with e-stop integration
- Factory automation and industrial control requiring OSSD signal switching
- Modular safety device deployment across production lines with Point-to-Point or daisy-chain GuardLink topologies
- Systems requiring visibility of safety status at individual access points
Compatibility & Replacements
Compatible With
- Guardmaster GuardLink Safety System
- Guardmaster Dual GuardLink safety relay modules
- GuardLink-enabled smart safety devices (taps, switches, light curtains)
- Power to Release (PTR) guard locking switches
- M12 X-coded circular connector receptacles
Replaces / Drop-In Replacement For
- Not a direct replacement for passive taps (e.g., 440S-PF5D). Verify compatibility with your system integrator before ordering.
- Predecessor GuardLink tap models may have different pin configurations; confirm control system specifications.
Works With
- GuardLink safety communication protocol
- Allen-Bradley Guardmaster safety management software
- M12 A/X-coded connector standard
- Rockwell Automation safety system architecture and wiring guidelines