Overview
The Eaton Edison ECNR 6/10 fuse is a Class RK5 dual-element, time-delay current-limiting fuse designed for motor circuit protection in industrial and commercial applications. This box of 10 units ensures a ready supply for maintenance and replacement needs. ECNR 6/10 fuses combine superior overload and cycling capabilities with reliable short-circuit protection, making them ideal for demanding electrical systems.
Key Features
- Dual-element construction with ferrule ends for secure contact and consistent performance
- Time-delay (slow-blow) design tolerates motor inrush current while protecting against sustained overloads
- Class RK5 current-limiting rating delivers fast fault clearing to minimize equipment damage
- Non-indicating design; fuse must be visually inspected or tested for status
- 200 kAIC interrupting rating at 250VAC for industrial-grade protection
- 8-second response at 500% load for coordinated motor circuit protection
Technical Specifications
The ECNR 6/10 fuse meets UL and industry standards for motor circuit protection:
- Current Rating: 6A and 10A (dual ratings in box of 10)
- Voltage Rating: 250VAC, 125VDC
- Fuse Class: RK5 (current-limiting)
- Type: Dual-element, time-delay
- Interrupting Rating: 200 kAIC at 250VAC; 20 kAIC at 125VDC
- Response Time: 8 seconds at 500% load
- End Configuration: Ferrule × ferrule
- Indicating: Non-indicating
- Packaging: Box of 10 fuses
Typical Applications
ECNR 6/10 fuses are widely used for:
- AC motor circuit protection and overload coordination
- Industrial control systems and motor starters
- HVAC and refrigeration equipment motor protection
- Machine tool and automation motor circuits
- Ground fault and short-circuit protection in supply lines
- Backup fuse inventory for replacement and maintenance
Compatibility & Replacements
Compatible With
- Standard ferrule-end fuse holders rated for Class RK5
- Eaton/Bussmann motor starter and control enclosures
- Industrial panel and disconnect switch fuse receptacles
- Electrical distribution systems rated 250VAC or 125VDC
- UL-listed motor circuit protection schemes
Replaces / Drop-In Replacement For
- Previous Eaton Edison ECNR 6A and 10A fuse inventory
- Bussmann ECNR6 and ECNR10 individual units
- Equivalent Class RK5 dual-element time-delay fuses from other manufacturers (verify part compatibility)
Works With
- Standard AC motor starter contactors and overload relays
- UL 508 industrial control panels and motor control centers
- Eaton Cutler-Hammer motor starter assemblies
- Allen-Bradley and other OEM motor protection circuits
- NEMA-rated electrical enclosures and switchgear