Overview

Allen-Bradley 1756-IR6I is an analog isolated RTD input module designed for seamless integration into ControlLogix 1756 chassis. This module provides six individually isolated Resistance Temperature Detector (RTD) input channels with 16-bit resolution, enabling accurate and noise-immune temperature measurement across multiple sensor locations in a single compact slot.

Key Features

  • Six Isolated RTD Inputs: Channel-to-channel isolation reduces noise and improves accuracy in multi-point temperature sensing applications.
  • 16-Bit Resolution: Scales from 7.7 mΩ/bit to 60 mΩ/bit depending on selected input range.
  • Configurable Input Ranges: Supports 1–487 Ω, 2–1,000 Ω, 4–2,000 Ω, and 8–4,000 Ω resistance ranges.
  • Multiple RTD Support: Compatible with Pt100, Pt200, Pt500, Pt1000 (alpha=385 and 3916), Ni100, Ni120, and Cu10 sensors.
  • Data Format Flexibility: Integer mode (16-bit) or IEEE 32-bit floating-point with temperature linearization, digital filtering, and process/rate alarms.
  • Built-in Diagnostics: Underrange/overrange detection, notch filter for line-noise rejection, and real-time channel sampling.

Technical Specifications

  • Input Channels: 6 isolated RTD/resistor inputs
  • Resolution: 16-bit digital
  • Input Ranges: 1–487 Ω | 2–1,000 Ω | 4–2,000 Ω | 8–4,000 Ω
  • Resolution per Range: 7.7 mΩ/bit | 15 mΩ/bit | 30 mΩ/bit | 60 mΩ/bit
  • Backplane Current (5.1 VDC): 250 mA typical
  • Backplane Current (24 VDC): 125 mA typical
  • Power Dissipation (Max): 4.3 W
  • Operating Temperature: 0–60°C
  • Scan Time (Resistance): 25 ms per channel
  • Scan Time (Temperature): 50 ms per channel
  • Physical Format: Single-slot ControlLogix module (20-pin connector)
  • Terminal Block Options: 1756-TBNH or 1756-TBSH (removable)
  • Certifications: UL, CE, CSA, RoHS compliant

Typical Applications

The 1756-IR6I excels in demanding environments requiring multi-point temperature monitoring. Common uses include:

  • Process control and batch operations in food, chemical, and pharmaceutical industries
  • Furnace and oven temperature mapping and regulation
  • HVAC systems and thermal loop control
  • Refrigeration and cold-chain monitoring
  • Machine health monitoring and predictive maintenance
  • Environmental chamber control and lab automation

Compatibility & Replacements

Compatible With

  • ControlLogix 1756 chassis (all generations)
  • Studio 5000 / RSLogix 5000 programming software
  • EtherNet/IP industrial networks
  • PROFINET gateways and bridges
  • DeviceNet and ControlNet adapters
  • All Logix5000-based controllers

Replaces / Drop-In Replacement For

  • Earlier revisions of Allen-Bradley 1756-IR6I (Rev A and earlier)
  • Verify exact firmware compatibility with your system integrator for legacy installations

Works With

  • Software: Studio 5000 (v32+), RSLogix 5000, FactoryTalk View
  • Protocols: EtherNet/IP, PROFINET, DeviceNet, ControlNet
  • Backplane: ControlLogix 1756 I/O slot interface
  • Sensors: Any 2-wire, 3-wire, or 4-wire RTD (Pt100, Pt1000, Ni100, Cu10, etc.)
Condition

New No Box

Part Number

1756-IR6I /A

Manufacturer

Allen-Bradley (Rockwell Automation)

Module Type

Analog Input – Isolated RTD

Input Channels

6 isolated RTD/resistor inputs

Resolution

16-bit digital

Input Ranges

1–487 Ω, 2–1,000 Ω, 4–2,000 Ω, 8–4,000 Ω

Backplane Current

250 mA @ 5.1 VDC, 125 mA @ 24 VDC

Max Power Dissipation

4.3 W

Operating Temperature

0–60°C

Connector

20-pin ControlLogix (removable terminal block)

Supported RTDs

Pt100/200/500/1000 (α=385, 3916), Ni100/120/200/500 (α=618, 672), Cu10

Data Formats

16-bit integer, IEEE 32-bit floating-point

Certifications

UL, CE, CSA, RoHS

Top Brands for PLC Machinery