The IDEC RTE-P2AD24 is a signal-triggered multifunction electronic timer relay engineered for industrial automation, HVAC systems, and general control applications. This 24VAC/DC-powered device provides exceptionally flexible timing control with switchable functions and adjustable delay ranges. The compact 11-pin plug-in format and dual DPDT (2 Form C) contact configuration make it ideal for retrofits and new installations in standard relay sockets.
Key Features
- Six Distinct Timing Functions: ON-delay, OFF-delay, cycle OFF, cycle ON, signal ON/OFF delay, and one-shot—selectable via external switches
- Broad Delay Range: 0.1 seconds to 600 hours across 20 selectable time ranges
- Dual DPDT Contacts: 2 Form C delayed outputs rated 10A @ 240VAC or 30VDC; 1/6 HP @ 120VAC; 1/3 HP @ 240VAC
- High Repeat Accuracy: ±0.2% timing accuracy ensures consistent performance across thousands of cycles
- LED Status Indicators: Power and timing-out LEDs for quick visual diagnostics
- Universal Mounting: Plug-in socket or 45 mm panel-mount adaptor compatible; DIN rail or surface options
Technical Specifications
- Operating Voltage: 24VAC / 24VDC
- Contact Configuration: 2 Form C, DPDT (dual changeover)
- Contact Rating: 10A @ 240VAC, 30VDC
- Horsepower Ratings: 1/6 HP @ 120VAC; 1/3 HP @ 240VAC
- Timing Range: 0.1 sec to 600 hours (20 selectable ranges)
- Timing Accuracy: ±0.2% repeat accuracy
- Reset Time: 100 ms maximum
- Mechanical Life: 50,000,000 operations minimum
- Operating Temperature: −20 to +65 °C (−4 to +149 °F)
- Operating Humidity: 35 to 85% RH (non-condensing)
- Terminal Style: 11-pin plug-in socket
- Dimensions: 40 mm H × 36 mm W × 74.9 mm D
- Approvals: CE marked, UL listed
Typical Applications
- Building Automation Systems (BAS): Scheduled lighting, fan cycles, equipment start/stop delays
- HVAC Control: Compressor soft-start, damper sequencing, occupancy-based shutdowns
- Industrial Machinery: Guard interlocks, motor ramp-up sequences, coolant pump cycles
- Safety Systems: Emergency shutdown delays, backup power switchover timing
- Irrigation & Pumping: Cycle ON/OFF for pressure tank control, sequential valve sequencing
Compatibility & Replacements
Compatible With
- IDEC relay sockets and plug-in modules
- Standard 11-pin socket-mounted relay bases
- DIN-rail mounting systems with adaptor
- Panel-mount applications with optional 45 mm cutout adaptor
- 24VAC/DC distributed control systems and PLCs
Replaces / Drop-In Replacement For
- IDEC RTE-B2AD24 (same function group, different base type)
- Earlier IDEC RTE series multifunction timers with 24V coil and DPDT contact
- Generic electromechanical multifunction timers with 11-pin plug-in configuration
Works With
- IDEC standard relay sockets and mounting adapters
- 24VAC/DC hardwired control circuits
- Distributed I/O modules and terminal block systems
- Legacy and modern industrial control panels
- BACnet, open protocol building automation systems