Fuses & Links

Lot of 6 Bussmann Fusetron FRN-R-60 Dual Element Limiting Class RK5 Fuse

Price
$48.00

Guaranteed Safe Checkout

Payment Methods
Buy Now
SKU Condition Availability
C-1-F-188 Surplus - Open Box 1 in stock
Free Shipping
On orders over $50
Easy Returns
30-day return policy
Secure Payment
100% secure

Overview

The Bussmann FRN-R-60 Fusetron is an energy-efficient dual-element, time-delay Class RK5 fuse rated 60 amperes at 250 Vac and 125 Vdc. It delivers both motor overload protection and current-limiting short-circuit protection in a single ferrule-terminal cartridge. The FRN-R-60 is designed for use in motor feeders, branch circuits, and equipment where selective coordination and reduced energy costs are priorities.

Key Features

  • Dual-element construction: Provides separate overload and short-circuit protection paths
  • Time-delay operation: Withstands 500% rated current for minimum 10 seconds, allowing motor inrush currents to pass safely
  • Current-limiting design: Opens in as little as 0.004 second during short-circuit conditions, reducing peak fault current and arc damage
  • Class RK5 rejection: Fits standard Class H, K, or R fuse blocks with notch-and-groove design
  • UL Listed: Meets UL 248-12 and CSA standards for reliable, code-compliant protection
  • Energy efficient: Minimizes nuisance outages and improves power system efficiency in three-phase applications

Technical Specifications

Amperage Rating 60 A
Voltage Rating 250 Vac / 125 Vdc
Interrupting Rating 200 kA (symmetrical) at 250 Vac; 20 kA at 125 Vdc
Fuse Class RK5 (Class R)
Type Dual-element, time-delay cartridge
Time-Delay Response 10 seconds minimum at 500% rated current
Body Material Ceramic with fiberglass layers
Terminal Type Ferrule (clip-on / screw-in block mount)
Diameter 0.81 inch
Length 3 inches
Approvals UL 248-12, CSA, CE
Series Bussmann Fusetron FRN-R
Catalog Number FRN-R-60 (non-indicating model)

Typical Applications

  • Motor feeder and branch circuit protection
  • Industrial machinery and HVAC systems requiring selective coordination
  • Single-phase and three-phase motor circuits
  • Pump and compressor protection circuits
  • Commercial electrical panels and disconnect switches
  • Heavy-duty applications where nuisance outages must be minimized

Compatibility & Replacements

Compatible With

  • Class H fuse blocks (with fuse reducer)
  • Class K fuse blocks (with fuse reducer)
  • Class R fuse blocks and holders (recommended)
  • Motor control circuits and thermal overload relays
  • Disconnect switches rated for Class R fuses

Replaces / Drop-In Replacement For

The FRN-R-60 directly replaces other Bussmann Fusetron FRN-R-60 units. Verify compatibility with your fuse block or disconnect switch before ordering, as Class R fuses require properly rated Class R equipment for safe operation. Consult your system integrator or electrical contractor if uncertain about replacement compatibility.

Works With

  • Standard motor starter and contactor circuits
  • Industrial control systems and PLCs
  • Fuse block reducers (specify Class for conversion from H or K)
  • Selective coordination schemes in multi-level power distribution
  • Compatible with both ferrule and knife-blade fuse applications (ferrule terminal only)
Amperage Rating

60 A

Voltage Rating

250 Vac / 125 Vdc

Interrupting Rating

200 kA @ 250 Vac, 20 kA @ 125 Vdc

Fuse Class

RK5 (Class R)

Type

Dual-element, time-delay cartridge

Time-Delay Response

10 seconds minimum at 500% rated current

Body Material

Ceramic with fiberglass

Terminal Type

Ferrule (clip-on / screw-in mount)

Diameter

0.81 inch

Length

3 inches

Approvals

UL 248-12, CSA, CE

Series

Fusetron FRN-R

Catalog Number

FRN-R-60

Top Brands for PLC Machinery

Scroll to Top