Overview
The ITI GFL080X116-2 ground fault sensor is a proven zero-sequence current transformer engineered for ground fault detection systems. This sensor is paired with ITI BGFL ground fault relays to monitor ac power systems and initiate protective trips when fault currents exceed pre-set thresholds. The GFL080X116-2 is rated for 30–360A trip current range and meets industry protection standards for electrical equipment.
Key Features
- Zero-sequence detection technology isolates ground faults from normal load currents
- Integral test winding enables combined sensor and relay testing without external injection equipment
- Rated for 50/60 Hz operation on single-phase ac systems
- 600 Volt insulation, 10 kV BIL (Basic Impulse Level) withstand capability
- Compact window-type design fits standard DIN or panel mounting configurations
- No. 8-32 brass terminal connections with lock washers for secure field termination
Technical Specifications
| Part Number | GFL080X116-2 |
| Manufacturer | ITI Instrument Transformers Inc. |
| Sensor Type | Zero-Sequence Ground Fault Sensor |
| Trip Current Range | 30–360 Amperes |
| System Voltage | 600 VAC |
| Insulation Rating | 10 kV BIL Full Wave |
| Frequency | 50/60 Hz |
| Test Winding | Integral test winding included |
| Terminal Type | No. 8-32 Brass with Flat & Lock Washers |
| Compatible Relays | BGFL, GFP, GFPV Series |
Typical Applications
- Ground fault protection in commercial and industrial ac power distribution systems
- Standalone or integrated ground fault relay systems for equipment protection
- Power system fault monitoring where personnel safety is not the primary concern (per NEC)
- Retrofit installations in existing BGFL or GFP relay schemes
- Maintenance and service replacement in established ground fault protection circuits
Compatibility & Replacements
Compatible With
- ITI BGFL ground fault relays (all series)
- ITI GFP ground fault protection relays
- ITI GFPV ground fault protection with verification relays
- Single-phase ac power systems, 50/60 Hz
- Ground fault monitoring in service entrance and sub-panel circuits
Replaces / Drop-In Replacement For
- Verify exact model compatibility with system integrator. GFL sensor interchangeability depends on window size and amperage rating. Common similar models: GFL040X116-2, GFL080X120-2 (confirm specs before ordering)
Works With
- BGFL relay systems for ground fault detection and trip initiation
- Shunt trip disconnect devices or contactor coils for fault clearing
- Primary injection test systems and secondary test equipment
- Integral test winding allows system verification without external test equipment