Fuses & Links

Bussmann 30A 600V Fuse LPS-RK-30 (lot of 3)

Price
$25.00

Guaranteed Safe Checkout

Payment Methods
Buy Now
SKU Condition Availability
B-5-A-4-2 Surplus - Open Box 1 in stock
Free Shipping
On orders over $50
Easy Returns
30-day return policy
Secure Payment
100% secure

Overview

The Bussmann LPS-RK-30 is a Class RK1 dual-element, time-delay current-limiting fuse rated for 30A at 600VAC (300VDC). This three-pack of Low-Peak fuses provides fast short-circuit protection while tolerating normal motor inrush currents, making them essential for reliable circuit protection in industrial automation, power distribution, and equipment control systems.

Key Features

  • Dual-Element, Time-Delay Design: Permits sizing as close as 130% of motor full load amps for selective coordination without nuisance trips
  • High Interrupting Rating: 300 kA at 600VAC / 100 kA at 300VDC for dependable protection against severe faults
  • Current-Limiting Protection: Protects downstream components from thermal and magnetic stress during short circuits
  • Class RK1 Construction: Industry-standard UL and CSA certified cartridge fuse with 2:1 ampacity ratios for easy selective coordination
  • Proven Low-Peak Performance: Reduces fuse inventory by up to 33% when replacing older H, K, or RK5 classes

Technical Specifications

  • Voltage Rating: 600VAC / 300VDC
  • Current Rating: 30A
  • Fuse Class: RK1
  • Type: Dual-element, time-delay
  • Interrupting Rating: 300 kA @ 600VAC; 100 kA @ 300VDC
  • Time Delay: 10 seconds at 500% overload
  • Body Style: Cylindrical ferrule cartridge
  • Dimensions: 0.815" Dia × 5.004" Long (20.6mm × 127mm)
  • Weight: ~2.24 oz per fuse
  • Certifications: UL, CSA, CE
  • Manufacturer: Eaton Bussmann
  • Standard Package: Lot of 3 fuses

Typical Applications

  • Feeder and branch circuits in industrial control panels
  • Motor starter protection and backup overload defense
  • Transformer primary and secondary circuit protection
  • Solenoid and contactor branch protection
  • General-purpose industrial power distribution
  • OEM equipment where selective coordination is required

Compatibility & Replacements

Compatible With

  • Standard North American fused disconnect switches (Class RK1 compatible)
  • Motor control centers (MCCs) with RK1 fuse holders
  • Industrial panel boards and load centers rated for RK1 fuses
  • Power distribution equipment utilizing 600V three-phase systems
  • Backup overload protection for DOL and soft-starter motor circuits

Replaces / Drop-In Replacement For

  • LPS-RK-30 (non-indicating variants)
  • LPS-RK-30SP (current Eaton Bussmann designation)
  • Older Bussmann class H, K, and RK5 fuses at 30A 600V ratings where RK1 compatibility is available
  • Cooper Bussmann LPS-RK-30 legacy part numbers

Works With

  • Class RK1 fuse holders and clips
  • Standard North American electrical distribution systems
  • Both AC and DC circuits (600VAC primary, 300VDC secondary)
  • Selective coordination schemes using 2:1 ampacity spacing
  • Standard IEC and UL-listed control equipment
Manufacturer

Eaton Bussmann

Part Number

LPS-RK-30 / LPS-RK-30SP

Current Rating

30A

Voltage Rating

600VAC / 300VDC

Fuse Class

RK1

Type

Dual-element, time-delay, current-limiting

Interrupting Rating

300 kA @ 600VAC; 100 kA @ 300VDC

Time Delay

10 seconds at 500% overload

Body Style

Cylindrical ferrule cartridge

Dimensions

0.815" Dia × 5.004" Long (20.6mm × 127mm)

Weight

~2.24 oz per fuse

Certifications

UL, CSA, CE

Package Contents

Lot of 3 fuses

Top Brands for PLC Machinery

Scroll to Top