Fuses & Links

Edison ECNR20 250V 20A RK5 Fuse (Box of 10)

Price
$59.99

Guaranteed Safe Checkout

Payment Methods
Buy Now
SKU Condition Availability
C-3-3-48 Surplus - Original Packaging 1 in stock
Free Shipping
On orders over $50
Easy Returns
30-day return policy
Secure Payment
100% secure

Overview

The Edison ECNR20 is a dual-element, time-delay class RK5 fuse designed for reliable overcurrent protection in industrial and commercial electrical systems. With a voltage rating of 250V AC and 125V DC, and a 20-ampere current rating, the ECNR20 offers current-limiting protection with superior overload and cycling capabilities. The ferrule-end configuration provides secure connections in standard fuse holders, making this fuse ideal for motor circuits, transformer protection, and AC power distribution systems.

Key Features

  • Dual-Element, Time-Delay Design: True dual-element construction allows sizing of 125% FLA for motor backup protection, enabling circuit sizing closer to actual load current while maintaining overcurrent protection.
  • RK5 Class Current-Limiting: UL Listed, Class RK5, Guide JDDZ, File E162363; CSA Certified, meeting industry standards for performance and safety.
  • Extended Time-Delay: Minimum industry standard time-delay of 10 seconds at 5 times the fuse rating (8 sec. minimum for 250V, 30A and less), accommodating normal motor inrush without nuisance trips.
  • Ferrule-End Terminals: 0.56 In Diameter, 2 In Overall Length ferrule ends fit standard holders used in industrial control panels and distribution equipment.
  • Wide Application Range: Recommended for AC power distribution system mains, feeders and branch circuits having inductive loads (motors, transformers) or non-inductive loads (lighting, heating).

Technical Specifications

  • Current Rating: 20 Amperes
  • Voltage Rating: 250V AC / 125V DC
  • Fuse Class: RK5 (Current-Limiting)
  • Type: Dual-Element, Time-Delay
  • Terminal Configuration: Ferrule End × Ferrule End
  • Time-Delay Response: 8 seconds at 500% of rated current
  • Interrupting Rating (AIR): 200 kAIC at 250V
  • Diameter: 0.56 In
  • Length: 2 In
  • Weight per Unit: 0.50 LB
  • Package Contents: Box of 10 fuses

Typical Applications

In ratings up to 600A, ECNR/ECSR series fuses are one of the most popular styles used for industrial applications. The ECNR20 is especially suited for:

  • Three-phase motor branch circuits
  • AC power distribution main feeders and branch circuits
  • Transformer protection circuits
  • Lighting and heating circuits with inductive loads
  • Industrial facilities and machinery control systems

Compatibility & Replacements

Compatible With

  • Standard ferrule-end fuse holders (Class RK5 rated)
  • AC power distribution panels and switchboards
  • Motor control centers (MCC)
  • Industrial and commercial electrical systems rated 250V AC / 125V DC
  • Eaton/Bussmann fuse holder equipment

Replaces / Drop-In Replacement For

  • Bussmann ECNR20 (same manufacturer, same specifications)
  • Other Class RK5 20A 250V dual-element time-delay fuses with ferrule-end configuration
  • Previous generation Edison ECNR20 units (exact replacement)

Works With

  • Ferrule-end fuse holders and clips rated for RK5 class fuses
  • Panel-mounted fuse blocks in industrial control enclosures
  • UL-listed and CSA-certified equipment designed for Class RK5 fuses
  • Motor starters and overload protection relay systems
  • Power distribution equipment from Eaton, Square D, GE, and other major manufacturers

Part Number

ECNR20

Brand

Edison

Current Rating

20 Amperes

Voltage Rating

250V AC / 125V DC

Fuse Class

RK5 (Current-Limiting)

Type

Dual-Element, Time-Delay

Terminal Type

Ferrule End × Ferrule End

Interrupting Rating

200 kAIC @ 250V

Time-Delay Response

8 seconds @ 500%

Diameter

0.56 inches

Length

2 inches

Weight per Unit

0.50 lbs

Quantity per Box

10 fuses

Certifications

UL Listed (JDDZ), CSA Certified (C22.2 No. 248.12)