Yokogawa YTA110-EA2NB/FU1/D2 Temperature Transmitter
The Yokogawa YTA110-EA2NB/FU1/D2 is a high-performance temperature transmitter designed to deliver accurate and reliable temperature measurements in industrial applications. This model supports a 24V DC power supply and provides a 4 to 20 mA DC output signal with HART digital communication protocol, ensuring seamless integration into existing control systems.
Key Features
- Versatile Sensor Input: Compatible with various sensor types, including thermocouples (T/C), resistance temperature detectors (RTD), ohms, and DC millivolts, offering flexibility for diverse measurement needs.
- Digital Communication: Equipped with HART protocol, allowing for easy configuration and monitoring using standard communicators.
- High Accuracy: Delivers an accuracy of ±0.1% of the calibrated span, ensuring precise temperature readings.
- Cold Junction Compensation: For thermocouple inputs, it offers a cold junction compensation accuracy of ±0.5°C (±0.9°F), enhancing measurement reliability.
- Robust Design: Features a dual-compartment housing that provides high resistance to harsh environments, ensuring durability and long-term performance.
- Self-Diagnostics: Incorporates continuous self-diagnostics capabilities to maintain optimal operation and reduce maintenance costs.
- LCD Display: Comes with an integral digital indicator that displays both digital readouts and bar graphs simultaneously, facilitating easy monitoring.
Specifications
- Power Supply: Operates on a 24V DC power supply.
- Output Signal: Provides a 4 to 20 mA DC output with HART digital communication.
- Electrical Connection: Equipped with a 1/2 NPT female electrical connection.
- Mounting Bracket: Supplied without a mounting bracket.
- Calibration Unit: Calibrated in degrees Fahrenheit/Degree Rankine.
- Ambient Temperature Effect: Per 10°C change, the effect is ±0.1% or ±(Temperature Coefficient/span), whichever is greater.
- Stability: For RTD inputs, stability is ±0.1% of reading or ±0.1°C per 2 years at 23±2°C; for thermocouple inputs, it’s ±0.1% of reading or ±0.1°C per year at 23±2°C.
- Power Supply Effect: ±0.005% of calibration span per volt.
- Vibration Effect: 10 to 60 Hz with 0.21 mm peak displacement; 60 to 2000 Hz at 3G.
- Shipping Weight: Approximately 4 kg.
The Yokogawa YTA110-EA2NB/FU1/D2 temperature transmitter is engineered to meet the demanding requirements of industrial temperature measurement applications, offering precision, reliability, and ease of integration.